PMI Model No. TDC-30T-0110-CD-1 is a high speed, TTL logic output threshold detector with an input coupler designed to operate from 0.1 to 10 GHz.
Specifications:
Frequency Range |
0.1 to 10.0GHz |
Insertion Loss |
2.5dB max |
VSWR |
2.0:1 |
Frequency Flatness |
+/-1.5dB typ, +/-2.0dB max |
Threshold Level |
Adjustable |
Threshold Variation |
+/-0.5dB typ over any 1GHz |
Propagation Delay |
20ns max, 15ns typ |
Output Pulse Width When Input |
|
-20dBm to -10dBm |
Within 10ns of input pulse width |
-10dBm to 0dBm |
Within 10ns of input pulse width |
-10dBm to +10dBm |
Within 25ns of input pulse width |
-20dBm to +1-dBm |
Within 25ns of input pulse width |
DC Power Supply |
+12V @ 150mA max |
Size |
2.2" x 1.5" x 0.4" |
Finish |
Gold Plated |
Environmental Ratings:
Temperature: |
-55ºC to +85ºC Operating |
-65ºC to +100ºC Non-Operating |
|
Humidity: |
MIL-STD-202F, Method 103B Cond. B |
Shock: |
MIL-STD-202F, Method 213B Cond. B |
Vibration: |
MIL-STD-202F, Method 204D Cond. B |
Altitude: |
MIL-STD-202F, Method 105C Cond. B |
Temperature Cycle: |
MIL-STD-202F, Method 107D Cond. A |