Specifications:

Frequency Range

0.1 to 10.0GHz

Insertion Loss

2.5dB max

VSWR

2.0:1

Frequency Flatness

+/-1.5dB typ, +/-2.0dB max

Threshold Level

Adjustable

Threshold Variation

+/-0.5dB typ over any 1GHz

Propagation Delay

20ns max, 15ns typ

Output Pulse Width When Input

 

  -20dBm to -10dBm

Within 10ns of input pulse width

  -10dBm to 0dBm

Within 10ns of input pulse width

  -10dBm to +10dBm

Within 25ns of input pulse width

  -20dBm to +1-dBm

Within 25ns of input pulse width

DC Power Supply

+12V @ 150mA max
-12V @ 100mA max

Size

2.2" x 1.5" x 0.4"

Finish

Gold Plated

Environmental Ratings:

Temperature:

 -55ºC to +85ºC Operating

 -65ºC to +100ºC Non-Operating

 Humidity:

 MIL-STD-202F, Method 103B Cond. B

 Shock:

 MIL-STD-202F, Method 213B Cond. B

 Vibration:

 MIL-STD-202F, Method 204D Cond. B

 Altitude:

 MIL-STD-202F, Method 105C Cond. B

 Temperature Cycle:

 MIL-STD-202F, Method 107D Cond. A